Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Int J Prosthodont ; 36(2): 194-202, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-33625399

RESUMO

PURPOSE: To investigate the discoloration and surface properties of four CAD/CAM composite resins following storage in various food solutions and exposure to cigarette smoke. MATERIALS AND METHODS: A total of 74 specimens (N = 370) were prepared for five materials: Brilliant Crios (BC), Cerasmart (GC), Lava Ultimate (LU), Shofu Block HC (SH), and Sonic Fill 2 (SO). Discoloration (ΔE) was investigated with a spectrophotometer. Measurements were taken before immersion in storage media (carrot juice, curry, cigarette smoke, red wine, energy drink, and distilled water), after 2 weeks of immersion, and after manual polishing of the specimens following immersion. The average surface roughness (Ra) was measured with a profilometer. Qualitative surface observation was performed with scanning electron microscopy (SEM). Data were analyzed using Kolmogorov-Smirnov test, Mann-Whitney U test, and one-way ANOVA with Tukey post hoc test. RESULTS: The highest influence on ΔE after immersion was observed for storage medium (ηηP2 = 0.878, P < .001), followed by the interaction between storage medium and material (ηP2 = 0.770, P < .001) and material (ηP2 = 0.306, P < .001). For ΔE after polishing, the highest influence was indicated by the interaction between material and medium (ηP2 = 0.554, P < .001), followed by medium (ηP2 = 0.244, P < .001) and material (ηP2 = 0.196, P < .001). Immersion in carrot juice led to the highest color change (ΔE: 8.0 to 10.4), whereas the lowest values were recorded in distilled water (ΔE: 2.0 to 2.4). Carrot juice and the energy drink caused the highest Ra values (0.120 µm to 0.355 µm). SEM pictures indicated a loss of the organic matrix after manual polishing. CONCLUSION: The different materials reacted dissimilarly to the various storage media in terms of discoloration. Surface roughness increased after immersion or polishing. Neither discoloration nor surface roughness could be reset to default by manual polishing. Int J Prosthodont 2023;36:194-202. doi: 10.11607/ijp.6950.


Assuntos
Fumar Cigarros , Resinas Compostas , Projetos de Pesquisa , Água , Propriedades de Superfície , Teste de Materiais , Cor
2.
BMC Med Educ ; 22(1): 180, 2022 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-35291993

RESUMO

PURPOSE: During our transthoracic echocardiography (TTE) courses, medical students showed difficulty in spatial orientation. We implemented the use of 3D printed cardiac models of standard TTE views PLAX, PSAX, and A4C and assessed their efficacy in TTE-teaching. METHODS: One hundred fifty-three participants were split into two groups. A pre-test-retest of anatomy, 2D -, and 3D orientation was conducted. The intervention group (n = 77) was taught using 3D models; the control group (n = 76) without. Both were comparable with respect to baseline parameters. Besides test-scores, a Likert scale recorded experiences, difficulties, and evaluation of teaching instruments. RESULTS: From the 153 students evaluated, 123 improved, 20 did worse, and ten achieved the same result after the course. The median overall pre-test score was 29 of 41 points, and the retest score was 35 (p < 0.001). However, the intervention group taught with the 3D models, scored significantly better overall (p = 0.016), and in 2D-thinking (p = 0.002) and visual thinking (p = 0.006) subtests. A backward multivariate linear regression model revealed that the 3D models are a strong individual predictor of an excellent visual thinking score. In addition, our study showed that students with difficulty in visual thinking benefited considerably from the 3D models. CONCLUSION: Students taught using the 3D models significantly improved when compared with conventional teaching. Students regarded the provided models as most helpful in their learning process. We advocate the implementation of 3D-printed heart models featuring the standard views for teaching echocardiography. These findings may be transferable to other evidence based medical and surgical teaching interventions.


Assuntos
Orientação Espacial , Estudantes de Medicina , Ecocardiografia , Humanos , Modelos Anatômicos , Impressão Tridimensional
3.
J Dent ; 117: 103916, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34875273

RESUMO

OBJECTIVES: This in vitro study compares the scanning accuracy of various stationary and portable as well as extra- and intraoral devices for capturing oncological defects. METHODS: A 3D-printed model of a nasal, orbital, and auricular defect, as well as one of an intact auricle, were digitalized (n = 7 per device) with a stationary optical scanner (Pritiface), a portable extraoral optical scanner (Artec Space Spider), two intraoral scanners (Trios 4 and Primescan), and a smartphone (iPhone 11 Pro). For the reference data, the defect models were digitalized using a laboratory scanner (D2000). For quantitative analysis, the root mean square error value for trueness and precision and mean deviations in millimeters were obtained for each defect type. The data were statistically analyzed using two-way ANOVA and Tukey multiple comparison test. For qualitative analysis, a colorimetric map was generated to display the deviation within the defect area and adjacent tissue. RESULTS: Statistically significant interactions were found in the trueness and precision for defect and scanner type. CONCLUSION: The Primescan and Artec Space Spider scanners showed the highest accuracy for most defect types. Primescan and Trios 4 failed to capture the orbital defect. The iPhone 11 Pro showed clinically acceptable trueness but inferior precision. CLINICAL SIGNIFICANCE: The scanning devices may demonstrate varying accuracy, depending on the defect type. A portable extraoral optical scanner is an universal tool for the digitization of oncological defects. Alternatively, an intraoral scanner may be employed in maxillofacial prosthetics with some restrictions. Utilizing a smartphone in maxillofacial rehabilitation should be considered with caution, because it provides inconsistent accuracy.


Assuntos
Técnica de Moldagem Odontológica , Modelos Dentários , Desenho Assistido por Computador , Imageamento Tridimensional , Smartphone
4.
J Clin Med ; 8(6)2019 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-31159171

RESUMO

Polyetheretherketone (PEEK) is a prime candidate to replace metallic implants and prostheses in orthopedic, spine and cranio-maxillofacial surgeries. Fused-filament fabrication (FFF) is an economical and efficient three-dimensional (3D) printing method to fabricate PEEK implants. However, studies pertaining to the bioactivity of FFF 3D printed PEEK are still lacking. In this study, FFF 3D printed PEEK samples were fabricated and modified with polishing and grit-blasting (three alumina sizes: 50, 120, and 250 µm) to achieve varying levels of surface roughness. In vitro cellular response of a human osteosarcoma cell line (SAOS-2 osteoblasts, cell adhesion, metabolic activity, and proliferation) on different sample surfaces of untreated, polished, and grit-blasted PEEK were evaluated. The results revealed that the initial cell adhesion on different sample surfaces was similar. However, after 5 days the untreated FFF 3D printed PEEK surfaces exhibited a significant increase in cell metabolic activity and proliferation with a higher density of osteoblasts compared with the polished and grit-blasted groups (p < 0.05). Therefore, untreated FFF 3D printed PEEK with high surface roughness and optimal printing structures might have great potential as an appropriate alloplastic biomaterial for reconstructive cranio-maxillofacial surgeries.

5.
J Prosthet Dent ; 120(2): 303-308, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29429837

RESUMO

Direct silicone printing may be applied to the fabrication of maxillofacial prostheses, although its clinical feasibility is unknown. The present clinical report shows an early application of a directly printed silicone prosthesis for the rehabilitation of a nasal defect. Two extraoral scanning systems were used to capture the face and the defect. The virtual construction of the nasal prosthesis was performed with free-form software. Two prostheses were printed in silicone and post-processed by manual sealing and coloring. The clinical outcome was acceptable for an interim prosthesis; however, the marginal adaptation and color match were not satisfactory without further individualization.


Assuntos
Desenho Assistido por Computador , Prótese Maxilofacial , Nariz/anormalidades , Nariz/cirurgia , Impressão Tridimensional , Desenho de Prótese/métodos , Silicones/uso terapêutico , Adulto , Carcinoma de Células Escamosas/complicações , Corantes , Face/anatomia & histologia , Face/diagnóstico por imagem , Face/cirurgia , Feminino , Humanos , Imageamento Tridimensional , Cavidade Nasal/diagnóstico por imagem , Cavidade Nasal/cirurgia , Nariz/anatomia & histologia , Nariz/diagnóstico por imagem , Impressão Tridimensional/instrumentação , Implantação de Prótese , Software , Fluxo de Trabalho
SELEÇÃO DE REFERÊNCIAS